ArticleID: Q3052 Created: Suggested By: Daniel Saputra and Robert Stiver.
- Citect Scada Manual
- Citect Scada Software Protection Failure Detection
- Citect Scada Software Protection Failure Ppt
Industry | Industrial Automation |
---|---|
Fate | Acquired |
Founded | Sydney, Australia, 1973 |
Products | CitectSCADA Vijeo Citect Citect Facilities CitectHistorian Vijeo Historian Ampla |
Owner | AVEVA |
Website | sw.aveva.com/monitor-and-control/hmi-supervisory-and-control/citect-scada |
Citect is an industrial software product sold by Aveva.
AVEVA transportation solutions provide applications for tracking critical real-time and historic data, managing passenger communications and monitoring assets and functionality. Citect Platinum Integrator and Edison Automation, in close partnership with Citect Professional Services, were initially awarded a contract with the city to install the SCADA system at the T.L. Amiss Water Treatment Plant to monitor and control the water treatment process, the water distribution system, and the wastewater collection system.
It is displaying a message that 'Protection key is not found or licenced is not awailable from network'. Earlier time i used.Sentinel Protection Installer v7.1.1. for installing protection key. This time the same key was not detected by this driver. So I used version 7.2.1. So whether I have to modify any files in citect bin folder to solve. .EcoStruxure Power SCADA Operation 2020 is:.Free upgrade for customers with software assurance.Paid upgrade from PSO 9.0 and previous versions.Release date for PSO 2020 end of January 2020 About Power SCADA Operation 2020 Internal commercial information.
Citect was a software development company specialising in the Automation and Control industry. The main software products developed by Citect included CitectSCADA, CitectSCADA Reports, and Ampla.
History[edit]
Citect began as a subsidiary of Alfa Laval in 1973.[1] The company was then known as Control Instrumentation. A name change of the company took place to Ci Technologies, and then to Citect to take advantage of the well known name of its flagship software product, CitectSCADA.
Whilst Citect was considered to be a software development company, it also had a large Professional Services division, which was a key contributor to the success of the business.
In 2006, Citect Pty Ltd was acquired by the Schneider Electric group.[2]
At the end of 2008, Citect ceased trading as an independent company and all of its remaining operations were absorbed into Schneider Electric.
Products[edit]
Ampla[edit]
Ampla is Manufacturing Execution Systems (MES) software.
Cicode[edit]
Cicode is a programming language used by Citect SCADA software. The structure and syntax of Cicode is very similar to that of the Pascal programming language, the main difference being that it does not include pointers and associated concepts. Citect provides a rich programming API that includes sophisticated programming constructs such as concurrent tasks and semaphores.
A Cicode sample is shown below. The function is used to log information to a file.
CitectSCADA[edit]
Developer(s) | AVEVA |
---|---|
Stable release | |
Preview release | 2015 (7.50) |
Operating system | Microsoft Windows |
Website | https://sw.aveva.com/monitor-and-control/hmi-supervisory-and-control/citect-scada |
CitectSCADA is a HMI / SCADA software package supporting
- an extremely wide range of Schneider Electric and 3rd party PLCs (using vendor's OPC driver or its own native drivers) and
- a big collection of symbols of industrial equipments for drawing the application scenes
made by Citect with
- a design-time HMI/GUI construction tool (called Citect Graphics Builder) and
- a run-time application logics expressed in the Cicodeprogramming language.
Citect for DOS[edit]
Martin Roberts wrote Citect for DOS, released in 1987, as a response to the limited range of PC-based operator interface software available at the time. Citect for DOS consisted of a configuration database (in dBase format), a bitmap (256 colour raw format) and an animation file. The user would draw a representation of a facility using the readily available Dr Halo graphical package and placing 'Animation Points' in the desired location. 'Tags' were assigned in the configuration databases, equating to addresses within the programmable electronic devices Citect was communicating with. By referencing these tags at animation points using other configuration databases, the user could show the state of equipment such as running, stopped or faulted in real-time.
Citect for DOS could communicate with various programmable electronic devices via the various serial links offered by the device; some through direct PC serial port connections, others through 3rd party PC based cards designed to communicate with the target programmable electronic device. Software drivers were written for many protocols; its ability to communicate with a variety of devices - and to have new drivers written when required - became a primary selling point for Citect.
The runtime software ran on a DSI card; a 32 bit co-processor that was inserted into an available ISA slot in the PC. This was due to insufficient processing power available in the 286 and 386 PCs available at the time.
Citect for Windows[edit]
Citect Scada Manual
Version 1[edit]
During the early 1990s PC computational power had caught up and Microsoft Windows based software was becoming popular, so Citect for Windows was developed and released in 1992. It no longer needed the DSI card to run on a PC. The configuration methodology remained similar to Citect for DOS but became more intuitive under MS Windows. Citect for Windows was written as a direct response to a request by Argyle Diamonds. The company was originally intending to use a Honeywell system until a number of Arygle's site engineers talked Argyle around to Citect after highlighting the existing problems they were having with Honeywell systems on site. Argyle contributed $1 million to the development of Citect for Windows. To this day the 'ArgDig' alarm database (i.e. Argyle Digital) is still part of Citect.
Version 2[edit]
In 1993 BHP Iron Ore upgraded its Port Hedland operator interface to Citect for Windows. Being the largest installation attempted by Citect at the time, Version 1 was showing many limitations. Version 2 was developed to improve on these limitations. Key changes were made to the graphics configuration by Andrew Allan, including a move away from Dr Halo/Animation Point to the new 'CTG' (Citect Graphics) system. A CTG combined the old BMP/AN files into a single object based file that gave the user a WYSIWYG look when using the new drawing package. The Port Hedland scope of work required additional functionality not inherent in Citect for Windows, but due to the versatile nature of the software (in particular by the use of Cicode) many additional features were programmed.
Version 3 and 4[edit]
Version 3 of Citect for Windows was developed to build in much of the functionality that previously had to be programmed, such as indication of a communications failure to any programmable electronic device displaying real-time data. While version 2 tended to be a bit unstable, version 3 was quite robust. Version 4 was the same as Version 3 but ported to suit the 32 bit platform of Windows NT.
Version 5 and 6[edit]
At this time Citect for Windows had the dominant market share (in Australia) of PC based operator interface software but new competitor software was catching up to the features and functionality of Citect and gaining in popularity. Citect began to focus more on remaining competitive; version 5 was released containing mainly features aimed at keeping the software at the leading edge of the market. Version 6 continued this trend and included more SCADA-like functionality in addition to the poll-based real-time control system that still remains the core of the Citect software today.
Version 7[edit]
Version 7 was released in August 2007. A. This version is also the first version to support Windows Vista Operating system. Support for Windows 7, along with notable features such as Pelco Camera integration, was added in 2010 with the release of version 7.20.[3]CitectSCADA 2015 release on 2 July 2015[4]
Version 8[edit]
Citect Scada Software Protection Failure Detection
Version 8 was released in 2016, with an overhauled UI and support for Windows 10.[5]
References[edit]
- ^Engineers Australia[permanent dead link]
- ^Schneider Electric Agrees to Acquire Citect
- ^'What's New - CitectSCADA V7.20',Schneider Electric, Retrieved 20 October 2011.
- ^http://www.citect.schneider-electric.com/unlock-the-value/
- ^Ko, Raymond. 'About Citect SCADA 2016'. www.citect.schneider-electric.com. Retrieved 19 January 2017.